MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer

1- Used Illinois Instruments 6500 Headspace Oxygen Analyzer S/N: 65- 0773106 Illinois Instruments 6500 headspace analyzers offer high levels of performance technology and operator ease to fulfill the latest industry demands for accuracy and reliability. The oxygen detector utilizes a high purity, stabilized zirconia ceramic, and platinum sensor maintained within a high-temperature environment. The sensor produces a log output which is converted and linearized to yield a digital readout directly proportional to a sample’s oxygen content. Manufacturer Specification  Oxygen Range- Autoranging from 0.001 to 100%  Displays- Bright 4 Digit LED, Display Hold, Analyze, and Calibration Status Indicators Response Time- <5 seconds (O2), <10 seconds (CO2) Accuracy: Oxygen- 10 to 100%, 0.2% absolute (max 2% of reading) and ±1 on the last digit. 1 to 9.99%, 0.02% absolute (max 2% of reading) and ±1 on the last digit. 0 to 0.999%, 0.005 % absolute and ±1 on the last digit. Ambient Temperature- +5 to +40°C Internal Sample Pump- Processor Controlled Diaphragm Type Syringe Injection- Via Male Luer Syringe Adaptor (supplied) Enclosure- Epoxy Coated Steel, Polycarbonate Operators Panel Location: Azusa, CA 91702
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
Image for MJK0020 Illinois Instruments 6500 Headspace Oxygen Analyzer thumb
1- Used Illinois Instruments 6500 Headspace Oxygen Analyzer

S/N: 65- 0773106

Illinois Instruments 6500 headspace analyzers offer high levels of performance technology and operator ease to fulfill the latest industry demands for accuracy and reliability. The oxygen detector utilizes a high purity, stabilized zirconia ceramic, and platinum sensor maintained within a high-temperature environment. The sensor produces a log output which is converted and linearized to yield a digital readout directly proportional to a sample’s oxygen content.

Manufacturer Specification 

Oxygen Range- Autoranging from 0.001 to 100% 
Displays- Bright 4 Digit LED, Display Hold, Analyze, and Calibration Status Indicators
Response Time- <5 seconds (O2), <10 seconds (CO2)
Accuracy: Oxygen- 10 to 100%, 0.2% absolute (max 2% of reading) and ±1 on the last digit. 1 to 9.99%, 0.02% absolute (max 2% of reading) and ±1 on the last digit. 0 to 0.999%, 0.005 % absolute and ±1 on the last digit.
Ambient Temperature- +5 to +40°C
Internal Sample Pump- Processor Controlled Diaphragm Type
Syringe Injection- Via Male Luer Syringe Adaptor (supplied)
Enclosure- Epoxy Coated Steel, Polycarbonate Operators Panel

Location: Azusa, CA 91702